I ran out of tire cleaner today and also replaced my outlet hoses for my hydrominder. The outlet hoses were not creating the correct suction to pull the chemical.
Fuse blew again – update
Greg fixed my bay problem today.
1) First we narrowed it down to which function had the problem. It was just presoak.
2) Next we disconnected the presoak solenoid for that bay. This is to rule out a bad solenoid coil. Still had the problem.
3) Next disconnect the presoak wire in the equipment room. Not sure if we disconnected the right wire but still had the problem.
4) Next disconnect the presoak wire from the terminal block. This stopped the problem. Greg said that the wires were corroded. Which is bad. This fixed the problem.
5) The next step would have been to disconnect from the switch.
Fuse blew again – update
I tried a new relay and like Greg said it made no difference. One coil wire is going to the timer load the other to the 24 vac coil in. The throw wires goes to the equipment room.
One throw wire goes to the 24 volt power supply (white lower) and the other wire is not used? It makes no sense. I must have checked wrong. I was getting frustrated and tied to look at another bay then broke it. Had to figure out what the problem was then quit. I think I need to just rerun all new wire to the bay.
I forgot to mention that the relay switch goes back and forth making the noise. I believe this means that there is a wire short? Who knows? It also just does this when the throw wires are attached.