Roof-Mounted attic fan

Well, I purchased my attic fan today.  I went with the smallest fan it states it is for 1600 sq ft attics.  I am not sure why they do not go by cubic feet.  My equipment room is about 220 sq ft.  It was $54.95 and if it does not cool well I could add another I guess.

I need to get a larger ladder because I am a wimp and am afraid I will not be able to get back off the roof.

Also, it was hot today.

Cut the post cover

I marked the post by flipping the post over and comparing to the others.

Then cut with my table saw.  I was to lazy to mount the post.  Maybe tomorrow.  I am replacing the post that got stolen.

Bay problem – no water – Update

I replace the boom hose with a smaller hose and still no water was coming out in the bay.  I removed the weep intake and water came out from the pump.  Then I felt like a moron when I realized what the problem was.

 

I took off the tip and water came out of the wand.

The tip was clogged.  I replaced it and everything was okay.

Low pressure problems

My low pressure functions were not working in any bay.  The equipment room floor was wet and one wall in the bays was wet.  The presoak and tire cleaner was not working and when you disconnected the hose from the pump to the solenoid block the pump worked fine.

I really had no clue so I called Greg and he enlightened me on what the problem was.  I removed the check valves between the solenoid bank and the pump.  Then pressed on them with a screwdriver then reattached.  Both functions worked fine so I turned on the high pressure one bay at a time to try and find the broken low pressure check valve.  I had no luck.  The problem was the presoak and tire cleaner use the same check valve in the bay.  Which confused me with trouble shooting but not Greg. 

Bay problem – no water

There was a cracked fitting between the pump head and the unloader.  I decided to replace the fitting.  Then I decided to replace the hose that runs from the pump to the high pressure hose.  I assumed that it was the size of a swivel saver.  Which it was not.  I cut the hose with a grinder because it had no swivels on it.  Then I had to put a boom hose in its place but no water would come out at the bay.  The pump got super hot and I have no clue what the problem is.  So I gave up.  I will need to look at it tomorrow.

Rowe changer problems

I got two different errors today.  "L HOPPER EMPTY" which it was not and I am not sure what the problem was I checked the hopper and reset.  The second error was "EXTRA COIN-L HOP" just reset.